Voice coil actuator with housing
A VCA in the housing reduces the number of assembly steps
A voice coil actuator consists of two components: a coil on a carrier and a cylinder with permanent magnets. The force and direction of the coil are directly dependent on the direction and strength of the current.
Due to the low mass of the coil, you can achieve very high acceleration . The prerequisite for this is a correspondingly light load. The force required for acceleration can be over 1,100 N. As the Voice Coil Actuator is a direct drive, there are no losses due to the spindle or gearbox.
The voice coil actuators with housing consist of a voice coil actuator, a guide and a housing. This means you can easily install the VCA and quickly put the actuator into operation.
Voice coil actuators with a partial housing consist of a self-aligning bushing and a shaft. Their housing is therefore not complete. There are 3 shaft options for easier system integration: Standard, female thread or male thread.
We are guaranteed to find the right actuator for you - free of charge & without obligation
Advantages with housed voice coil
You have all the advantages of a voice coil, but they are quicker to install.
Realized locations
Scanner
Handheld devices
Staplers
Syringes
Optics adjustment
Features
-
Stroke from 4 to 51 mm
-
Peak force up to 2.44 kN
-
Continuous force up to 1.44 kN
-
Various sizes
LAH series models with housing
| Key data | Unit | LAH04-10 | LAH13-18 | LAH13-18 | LAH16-23 | LAH16-23 | LAH28-53 | LAH28-53 | LAH28-53 | LAH43-86 |
|---|---|---|---|---|---|---|---|---|---|---|
| LAH04-10-000A | LAH13-18-000A-3E | LAH13-18-000A-3S | LAH16-23-000A-4E | LAH16-23-000A-4S | LAH28-53-000A-12E | LAH28-53-000A-12I | LAH28-53-000A-12S | LAH43-86-000A | ||
| Peak force | (10s) N | 1.89 | 15.5 | 15.5 | 89.0 | 89.0 | 266 | 266 | 266 | 1,512 |
| Continuous force | N | 1.11 | 5.07 | 5.07 | 17.0 | 17.0 | 60.1 | 60.1 | 60.1 | 286 |
| Total stroke | mm | 4.0 | 6.3 | 6.3 | 6.0 | 6.0 | 25.0 | 25.0 | 25.0 | 31.7 |
| KA | N/√W | 0.84 | 2.36 | 2.36 | 5.83 | 5.83 | 13.0 | 13.0 | 13.0 | 38.3 |
| Outer-Ø | mm | 10.1 | 31.6 | 31.6 | 40.0 | 40.0 | 70.0 | 70.0 | 70.0 | 218 |
| Length plus ½ stroke | mm | 25.4 | 45.7 | 45.7 | 58.4 | 58.4 | 132 | 132 | 132 | 108 |
Models LA series with partial housing
| Key data | Unit | LA13-11 | LA13-11 | LA16-16 | LA16-16 | LA28-43 | LA28-43 | LA28-43 | LA100-93 | LA100-93 |
|---|---|---|---|---|---|---|---|---|---|---|
| LA13-11-001A-3E | LA13-11-001A-3S | LA16-16-001A-4E | LA16-16-001A-4S | LA28-43-001A-12E | LA28-43-001A-12I | LA28-43-001A-12S | LA100-93-001A-50I | LA100-93-001A-50S | ||
| Peak force | (10s) N | 15.5 | 15.5 | 89.0 | 89.0 | 266 | 266 | 266 | 2,447 | 2,447 |
| Continuous force | N | 5.07 | 5.07 | 24.4 | 24.4 | 75.6 | 75.6 | 75.6 | 1.443 | 1.443 |
| Total stroke | mm | 6.36 | 6.36 | 6.36 | 6.36 | 25 | 25 | 25 | 50.8 | 50.8 |
| KA | N/√W | 2.36 | 2.36 | 5.83 | 5.83 | 13.0 | 13.0 | 13.0 | 86.2 | 86.2 |
| Outer-Ø | mm | 31.6 | 31.6 | 40.0 | 40.0 | 70.0 | 70.0 | 70.0 | 254 | 254 |
| Length plus ½ stroke | mm | 27.3 | 27.3 | 39.6 | 39.6 | 129 | 129 | 129 | 236 | 236 |
Standards and guidelines
REACH
RoHS2
We are guaranteed to find the right actuator for you - free of charge & without obligation